ASME A18.1:2020 pdf free download – Safety Standard for Platform Lifts and Stairway Chairlifts

02-16-2022 comment

ASME A18.1:2020 pdf free download – Safety Standard for Platform Lifts and Stairway Chairlifts
combination mechanical lock and electric contact: a combi-nation mechanical and electrical device with two relatedbut entirely independent functions that are
(a) to prevent operation of the driving machine by thenormal operating device, unless the door or gate is in theclosed position
(b) to lock the door or gate in the closed position andpreventit from being opened from the landing side, unlessthe platform is within the specified distance from thelanding
compensating-rope sheave switch: a device that automat-ically causes the electric power to be removed from thedriving-machine motor and brake when the compensatingsheave approaches its upper or lower limit of travel.contacts: see door or gate electric contact.
control: the system governing the starting, stopping,direc-tion of motion, acceleration, speed, and retardation of themoving member.
controller: a device or group of devices that serves tocontrol in a predetermined manner the apparatus towhich it is connected.
door or gate: the movable portion(s) of the platform orrunway entrance that closes the opening providingaccess to the platform or landing. It consists of one ormore panels that may be equipped with a vision panel.door or gate,manually operated: door or gate that isopened and closed by hand.
door or gate, power-operated: a door or gate that isopened and closed by a door or gate power-operator.door or gate, self-closing: a manually operated door orgate that closes when released or a power-operated dooror gate.
door or gate closer: a device that closes a door or gate bymeans of a spring or gravity.
door or gate electric contact: an electrical device,the func-tion of which is to prevent operation of the drivingmachine by the normal operating device unless thedoor or gate is in the closed position.
door or gate power-operator: a device or assembly ofdevices that opens a door or gate by power other thanby hand, gravity,springs, or the movement ofthe platform;and that closes the door or gate by power other than byhand, gravity, or the movement of the platform.
driving machine: see machine, driving.
ermergency stop switch: a device that, when manually oper-ated, causes the lift to halt its motion.
enforcing authority: see authority having jurisdiction.entrance hardware: all components of an entrance, exclu-sive ofthe frame,door panels,and locks, that are necessaryto maintain the position of the panels within the assembly.
factor of safety: the ratio of the ultimate strength to theworking stress of a member under maximum staticloading, unless otherwise specified in a particular rule.
full passenger enclosure: an assembly inclusive of the plat-form top, minimum 2000 mm (79 in.) tall walls, minimum2000 mm (79 in.) tall platform doors, and platform floor.gate: see door or gate.
governor: see speed governor.
governor pull-retarding means: a mechanical means ofdeveloping a sufficient force in the governor rope to acti-vate the platform or counterweight safeties or to trip thegovernor rope releasing carrier, where used. Suchmechanical means include, but are not limited to, rope-gripping jaws, clutch mechanisms,and traction arrange-ments.
governor pull-through tension (force): the magnitude of thetensile load developed in the moving governor rope afterthe governor rope-retarding means is actuated.
inclined platform lift: a guided, powered hoisting andlowering mechanism equipped with a seat to transportseated passengers along stairways.
inclined stairway chairlift: a guided, powered hoisting andlowering mechanism, equipped with a seat to transportseated passengers along stairways.
installation: a complete platform lift or stairway chairlift,including all machinery and equipment necessary for itsoperation.
installation,existing: an installation that has beencompleted or is under construction prior to the effectivedate of this Standard.
installation,new: any installation not classified as anexisting installation by definition, or an existing platformlift or stairway chairlift moved to a new location subse-quent to the effective date of this Standard.
installation, placed out of service: an installation whosepower feed lines have been disconnected from themachine disconnect switch.
labeled: equipment or materials to which has been
attached a label, symbol,or other identifying mark ofan independent certifying organization concerned with
product evaluation, that maintains periodic inspectionof production of labeled equipment or materials andby whose labeling the manufacturer indicates compliancewith appropriate standards or performance in a specifiedmanner.