UL-430:2015 pdf free download – STANDARD FOR SAFETY Waste Disposers

02-18-2022 comment

UL-430:2015 pdf free download – STANDARD FOR SAFETY Waste Disposers.
5.7 Film-coated wire (magnet wire)
5.7.1 The component requirements for film coated wire and Class 105 (A) insulation systems are not specified.
5.7.2 Film coated wire in intimate combination with one or more insulators, and incorporated in an insulation system rated Class 120 (E) or higher, shall comply with the magnet wire requirements in the Standard for Systems of Insulating Materials — General, UL 1446.
5.8 Gaskets and seals
5.8.1 Gaskets and seals that are relied upon to prevent water entrance into electrical compartments and flooding of electrically live parts shall comply with the requirements in Physical Properties of Gaskets and Seals Test, Section 40.
5.9 Ground-fault, arc-fault, and leakage current detectors/interrupters
5.9.1 Ground-fault circuit-interrupters (GFCI) for protection against electrical shock shall comply with the Standard for Ground-Fault Circuit-Interrupters, UL 943. The following statement, or equivalent, shall be included as a marking near the GFCI, or as an instruction in the manual: “Press the TEST button (then RESET button) every month to assure proper operation.”
5.9.2 Appliance-leakage-current interrupters (ALCI) for protection against electrical shock shall comply with the Standard for Appliance-Leakage-Current Interrupters, UL 943B.
5.9.3 With respect to 5.9.2, an ALCI is not considered an acceptable substitute for a GFCI when the National Electrical Code, ANSI/NFPA 70 requires a GFCI.
5.9.4 Equipment ground-fault protective devices shall comply with the Standard for Ground-Fault Sensing and Relaying Equipment, UL 1053, and the applicable requirements in the Standard for Ground-Fault Circuit-Interrupters, UL 943.
5.9.5 Arc-fault circuit-interrupters (AFCI) shall comply with the Standard for Arc-Fault Circuit-Interrupters, UL 1699. See Arc-Fault and Leakage Current Detectors/Interrupters, Section 26.
5.9.6 Leakage-current detector-interrupters (LCDI) and any shielded cord between the LCDI and appliance shall comply with the Standard for Arc-Fault Circuit-Interrupters, UL 1699. See Arc-Fault and Leakage Current Detectors/Interrupters, Section 26.
5.10 Heating elements and heaters
5.10.1 Electric resistance heating elements shall comply with the construction requirements in:
a) The Standard for Electric Heating Appliances, UL 499; or
b) The Standard for Sheathed Heating Elements, UL 1030.
5.10.2 Thermistor-type heaters (e.g. PTC and NTC heaters) shall comply with the Standard for
Thermistor-Type Devices, UL 1434.
5.11 Insulation systems
5.11.1 Materials used in a Class 105 (A) insulation system shall comply with the requirements in Insulation Systems, Section 17.
5.11.2 Materials used in an insulation system that operates above Class 105 (A) temperatures shall comply with the Standard for Systems of Insulating Materials — General, UL 1446.
5.11.3 All insulation systems employing integral ground insulation shall comply with the requirements specified in the Standard for Systems of Insulating Materials — General, UL 1446.
5.12 Marking and labeling systems
5.12.1 A marking and labeling system shall comply the requirements in Permanence of Marking Tests, Section 47.
5.13 Motors and motor overload protection
5.13.1 General
5.13.1.1 General-purpose type motors having a NEMA frame size shall comply with the requirements specified in 5.15.2. This includes fractional HP motors rated up to 1 HP (typically NEMA frame sizes 42, 48, or 56), and integral HP motors rated 1 HP and greater (typically NEMA frame sizes 140 — 449T).

Main Focus Download
UL-62841-2-5:2016 pdf free download – STANDARD FOR SAFETY Electric Motor-Operated Hand-Held Tools, Transportable Tools And Lawn And Garden Machinery – Safety一Part 2-5: Particular Requirements for Hand-Held Circular Saws UL Standards

UL-62841-2-5:2016 pdf free download – STANDARD FOR SAFETY Electric Motor-Operated Hand-Held Tools, Transportable Tools And Lawn And Garden Machinery – Safety一Part 2-5: Particular Requirements for Hand-Held Circular Saws

UL-62841-2-5:2016 pdf free download - STANDARD FOR SAFETY Electric Motor-Operated Hand-Held Tools, Transportable Tools And Lawn And Garden Machinery - Safety一Part 2-5: Particular Requirements for Hand-Held Circular Saws. NOTE For circular saws with a maximum blade diameter...
More
UL-62133:2017 pdf free download – STANDARD FOR SAFETY Secondary Cells and Batteries Containing Alkaline or Other Non-Acid Electrolytes – Safety Requirements for Portable Sealed Secondary Cells, and for Batteries Made From Them, for Use in Portable Applications UL Standards

UL-62133:2017 pdf free download – STANDARD FOR SAFETY Secondary Cells and Batteries Containing Alkaline or Other Non-Acid Electrolytes – Safety Requirements for Portable Sealed Secondary Cells, and for Batteries Made From Them, for Use in Portable Applications

UL-62133:2017 pdf free download - STANDARD FOR SAFETY Secondary Cells and Batteries Containing Alkaline or Other Non-Acid Electrolytes - Safety Requirements for Portable Sealed Secondary Cells, and for Batteries Made From Them, for Use in Portable Applications....
More

LEAVE A REPLY

Anonymous netizen Fill in information