11.9.5 Final measurements
The relevant subclause of IEC 61215-2:2016, test MQT 09, is applicable without modihcations.
11.9.6 Requirements
The relevant subclause of IEC 61215-2:2016, test MQT 09, is applicable without modifications.
11.10 UV preconditioning test (MOT 10)
This test of IEC 61215-2:2016 is applicable without modifications.
11.11 Thermal cycling test (MOT 11)
This test of IEC 61215-2:2016 is applicable without modifications.
The technology specific current which needs to be applied according to test MQT 11 of IEC 61215-2:2016, shall be equal to the STC peak power current.
11.12 HumidIty-freeze test (MQT 12)
This test of IEC 61215-2:2016 is applicable without modifications.
11.13 Damp heat test (MOT 13)
This test of IEC 61215-2:2016 is applicable without modifications.
11.14 Robustness of terminations test (MOT 14)
This test of IEC 61215-2:2016 is applicable without modifications.
11.15 Wet leakage current test (MOT 15)
This test of IEC 61215-2:2016 is applicable without modifications.
11.16 Static mechanical load test (MQT 16)
This test of IEC 61215-2:2016 is applicable without modifications.
11.17 Hail test (MOT 17)
This test of lEG 61215-2:2016 is applicable without modifications.
11.18 Bypass diode thermal test (MOT 18)
This test of lEG 61215-2:2016 is applicable without modifications.
11.19 Stabilization (MQT 19)
This test of IEC 61215-2:2016 is applicable with the following modifications:
For the definition of stabilization as per test MQT 19 of IEC 61215-2:2016, x = 0,01 shall be used for crystalline silicon PV modules.
Temperature is a critical parameter. For the measurement MQT 06.1 of IEC 61215-2:2016 it shall be ensured that measurement is performed at (25 ± 2) °C module temperature.
11.19.4 Other stabilization procedures
At present no alternative stabilization methods are applicable.
11.19.5 Initial stabilization (MQT 19.1)
Initial stabilization of c-Si modules shall be obtained by exposing all modules to sunlight (either real or simulated) to an irradiation dose level of  10 kWh/rn2. After this preconditioning all of the test modules shall be measured for STC power (MQT 06.1).
To fulfil MQT 19 requirements two intervals of at least 5 kWh/rn2 each are required. If stabilization is performed outdoors no module temperature limits apply.
After stabilization time is not critical. Perform all measurements within a comparable timeframe and state time in report.

Main Focus Download
UL-62841-2-5:2016 pdf free download – STANDARD FOR SAFETY Electric Motor-Operated Hand-Held Tools, Transportable Tools And Lawn And Garden Machinery – Safety一Part 2-5: Particular Requirements for Hand-Held Circular Saws UL Standards

UL-62841-2-5:2016 pdf free download – STANDARD FOR SAFETY Electric Motor-Operated Hand-Held Tools, Transportable Tools And Lawn And Garden Machinery – Safety一Part 2-5: Particular Requirements for Hand-Held Circular Saws

UL-62841-2-5:2016 pdf free download - STANDARD FOR SAFETY Electric Motor-Operated Hand-Held Tools, Transportable Tools And Lawn And Garden Machinery - Safety一Part 2-5: Particular Requirements for Hand-Held Circular Saws. NOTE For circular saws with a maximum blade diameter...
More
UL-62133:2017 pdf free download – STANDARD FOR SAFETY Secondary Cells and Batteries Containing Alkaline or Other Non-Acid Electrolytes – Safety Requirements for Portable Sealed Secondary Cells, and for Batteries Made From Them, for Use in Portable Applications UL Standards

UL-62133:2017 pdf free download – STANDARD FOR SAFETY Secondary Cells and Batteries Containing Alkaline or Other Non-Acid Electrolytes – Safety Requirements for Portable Sealed Secondary Cells, and for Batteries Made From Them, for Use in Portable Applications

UL-62133:2017 pdf free download - STANDARD FOR SAFETY Secondary Cells and Batteries Containing Alkaline or Other Non-Acid Electrolytes - Safety Requirements for Portable Sealed Secondary Cells, and for Batteries Made From Them, for Use in Portable Applications....
More

LEAVE A REPLY

Anonymous netizen Fill in information